Sonraí:

● Rated Current: 63-1600A
● Working Voltage: up to 690VAC~
● Poles Number: 3P, 4P



● Standard: IEC60947-3
Glaoigh Linn
Cur síos
Glaoigh Linn

 

● Rated Current: 63-1600A

● Working Voltage: up to 690VAC~

● Poles Number: 3P, 4P

● Standard: IEC60947-3

 

 

The EDX series disconnector switch is designed for use in AC 50Hz electrical systems with a rated voltage of up to 660V and DC voltage up to 440V. It is primarily used in power distribution equipment in industrial enterprises, providing a means for infrequent switching, circuit breaking, and electrical isolation.

 

 

The EDX series disconnector switch complies with the IEC60947-3 and GB14048.3 standards, ensuring its adherence to international safety and performance requirements.

 

 

 

1. Altitude not more than 2000m.

2. The range of ambient temperature is from 5 degree to 40 degree .

3. Relative humidity not more than 95%.

4. The environment without any explosive medium.

5. The environment without any rain or snow attacking.

If the product is expected to be used in the environment where temperature is over +40 degree or below -5 degree to 40 degree , uses shall tell it to the manufacture.

 

 

● The switch adopts a modular design and is suitable for making and breaking circuits or electrical isolation. Above 1000A is only used for electrical isolation.

● The switch has 3 poles, 4 poles (3 poles + switchable neutral pole).

● There is a mark window under the switch to indicate the on-off state of the contact, and a rear observation window can be provided as required to directly observe the on-off state of the contact to ensure the reliability and safety of the switch operation.

● The handle can be directly installed on the switch for operation (referred to as in-cabinet operation), or it can be operated outside the power distribution cabinet door (referred to as out-of-cabinet operation) through the extension shaft, providing convenient operation.

● When the breaking position is "0", two to three locks can be used to lock the handle to prevent misoperation.

 

 

EDX-160

EDX-250A

EDX-630A

125

160

200

250

315

400

500

630

1000

1000

1000

2200

2200

2200

12

12

12

AC-21B

125

160

200

250

315

400

500

630

AC-22B

125

160

200

250

315

400

500

630

AC-23B

125

160

200

250

315

400

500

630

400V

63

80

100

132

160

220

280

315

Rated short-time endurance current lcw (kA Rms) 1s

6

6

9

9

12.6

12.6

12.6

12.6

Rated breaking capacity Icn (A Rms) AC-23B 400V

1000

1080

1600

2000

2520

3200

4000

5040

Rated switching capacity Icm (A Rms) AC-23B 400V

1250

1600

2000

2500

3150

4000

5000

6300

Rated short-circuit switching capacity Icm (kA peak)

9.2

9.2

15.3

15.3

25.2

25.2

25.2

25.2

Mechanical life 400V

1400

1400

1400

1400

800

800

800

800

Electrical life 400V

200

200

200

200

200

200

200

200

6.5

6.5

10

10

21

21

21

21

EDX-1600A

1000

1250

1600

1000

2200

12

AC-21B

1000

1250

1600

AC-22B

1000

1250

1600

AC-23B

1000

1250

1600

400V

560

560

560

Rated short-time endurance current lcw (kA Rms) 1s

30

30

30

Rated breaking capacity Icn (A Rms) AC-23B 400V

1500

1875

2400

Rated switching capacity Icm (A Rms) AC-23B 400V

1500

1875

2400

Rated short-circuit switching capacity Icm (kA peak)

63

63

63

Mechanical life 400V

500

500

500

Electrical life 400V

100

100

100

37

37

37

 

 

A: EDX series Load Break Switch are commonly used in various industrial settings where high-power equipment or machinery is operated. They are often employed in power generation plants, substations, heavy machinery installations, industrial manufacturing processes, and other applications that involve the control and disconnection of large electrical currents.

A: Yes, EDX series Load Break Switch are available in various configurations to meet different application needs. They can be found in 3 or 4pole designs, with options for manual or motorized operation, load break or no-load break functionality, and specific features for specialized applications.

A: EDX series Load Break Switch compliant with Standard: IEC60947-3

A: When selecting EDX series Load Break Switch, important factors to consider include the maximum current rating, voltage rating, operating mechanism (manual or motorized), switching capabilities (load break or no-load break), environmental conditions, and any specific requirements of the application or industry in which it will be used.

A: The maximum current rating of EDX series Load Break Switch is 1600A.

Q: Can EDX series Load Break Switch provide short-circuit protection?

A: EDX series Load Break Switch itself is primarily designed for circuit disconnection and isolation rather than short-circuit protection.

A: Yes, there are EDX series Load Break Switch specifically designed for hazardous environments. These switches may be equipped with features such as explosion-proof enclosures or comply with certifications like ATEX or IECEx, making them suitable for use in potentially explosive atmospheres or other hazardous locations.

 